Description
■ Pure sine wave solar inverter
■ Output power factor 1
■ Built-in 80A MPPT solar charger
■ 2 units can be wired in parallel to create a split-phase system with 120V and 240V capabilities
■ Support parallel operation up to 3 units
■ WIFI remote monitoring (optional)
■ CAN/RS485 communication for BMS
■ Compatible to generator

| MODEL | PH18-3024 LV | PH18-3048 LV | PH18-6048 LV |
| Nominal Battery System Voltage | 24VDC | 48VDC | |
| INVERTER OUTPUT | |||
| Rated Power | 3000W | 3000W | 6000W |
| Surge Power | 6000W | 6000W | 12000W |
| Waveform | Pure sine wave | ||
| AC Voltage Regulation (Batt.Mode) | 120VAC ±5% | 120VAC ±5% | 240VAC ±5% (L-L) |
| Inverter Efficiency(Peak) | 90% | ||
| Transfer Time | 10ms (UPS / UL) 20ms (APL) | ||
| AC INPUT | |||
| Voltage | 120VAC | 120VAC | 240VAC |
| Selectable Voltage Range | 107~132VAC(UL) | 214~264VAC(UL) | |
| Frequency Range | 50Hz / 60Hz(Auto sensing) | ||
| BATTERY | |||
| Normal voltage | 24VDC | 48VDC | 48VDC |
| Floating Charge Voltage | 27.4VDC | 54.8VDC | 54.8VDC |
| Overcharge Protection | 30VDC | 60VDC | 60VDC |
| SOLAR CHARGER & AC CHARGER | |||
| Maximum PV Array Open Circuit Voltage | 450VDC | 250VDC | 250VDC |
| Maximum Solar Charge Current | 100A | 80A | 80A/80A |
| PV Array MPPT Voltage Range | 90-430VDC | 60-200VDC | 60-200VDC |
| PV Input Power | 4000W | 4000W | 4000W/4000W |
| Maximum Efficiency | 98% | ||
| Maximum AC Charge Current | 80A | 60A | 60A |
| Maximum Charge Current | 100A | 140A | 160A |
| MECHANICAL SPECIFICATIONS | |||
| Machine Dimension (W*H*D) | 329*485*134mm | 329*485*134mm | 315*500*235 |
| Package Dimension (W*H*D) | 425*575*229mm | 425*575*229mm | / |
| G.W | 12kg | 12kg | 20kg |
| N.W | 13.5kg | 13.5kg | 22kg |
| OTHER | |||
| Humidity | 5% to 95% Relative humidity (Non-condensing) | ||
| Operating Temperature | -10°C~50°C | ||
| Storage Temperature | -15℃ ~60℃ | ||