Online UPS – Hybrid Solar Inverter & ESS Manufacturer https://www.mustpower.com Must Energy Storage System Tue, 06 Aug 2024 03:38:24 +0000 en-US hourly 1 https://wordpress.org/?v=6.8.2 EH9115 Three Phase Series (10-300KVA) https://www.mustpower.com/product/eh9115-three-phase-series-10-300kva/ Tue, 06 Aug 2024 03:37:19 +0000 https://www.mustpower.com/?post_type=product&p=24501 Low Frequency Three Phase 3/3 Online UPS EH9115 series three-in-three-out power frequency double conversion online intelligent UPS is a second-generation power supply product that has been upgraded with years of experience in the UPS industry. This series of products adopts the world's top brand device design, highreliability all-digital processing technology, and intelligence. The human-machine dialogue interface and powerful intelligent network management provide reliable power protection for today's centralized server rooms, network management centers, computer centers, and various advanced industrial automation devices.]]> Product performance

• Full digital DSP control technology for accurate and fast data processing and excellent output performance. More reliable.
• IGBT frequency modulation intelligent rectification inverter technology, input power factor up to 0.99, input current harmonic reach to 3%; Making output voltage and current performance is even better.
• The whole unit efficiency is 92%; in ECO mode, the efficiency is over 98%, lowering the power loss.
• Wide utility input range and frequency range, It make the UPS suit for different power supply equipment. Like generators,etc.
• Large LCD touch screen, operation and information reading more convenient.
• Emergency switch EPO button for remote control.
• N+1 parallel redundant connection; Accept 100% unbalanced load; Compatible with generators
• Double utility and single utility input optional . It makes more safety power supply for user.
• The UPS charger can correct the charging parameters according to different environmental conditions. Optimized battery charging way. According to the type of battery, the number of batteries and the state of use of the battery, choose the best charging method. Extend battery’s life
• The number of battery cells of the UPS is optional from 29 to 34, and the default is 32 cells. If you need a cell number other than 32 cells, you need to inform when placing an order, client cannot set the battery cell number.
• Provide RS232, SNMP , GPRS , monitoring communication interfaces. Remote management and monitoring functions are available to facilitate customers various monitoring needs .

]]>
EH9315 Three Phase Series (20-40KVA) https://www.mustpower.com/product/eh9315-three-phase-series-20-40kva/ Wed, 06 Mar 2024 11:29:47 +0000 https://www.mustpower.com/?post_type=product&p=23905 High Frequency Three Phase(3/1) Online UPS The EH9315 series is a new generation of high-frequency 3/1 Phase Online UPS, which adopts advanced DSP digital control technology, which effectively improves product performance and system reliability. It has the characteristics of small size, light weight, and high work efficiency. Effectively solve power problems such as power failure, mains high voltage, mains low voltage, instantaneous voltage drop, damping oscillation, high voltage pulse, surge voltage, harmonic distortion, clutter interference, frequency fluctuations, etc.And provide the best power for the load environment.]]> Performance:

• Double conversion online design, output zero conversion time.

• Adopting DSP digital control, with excellent performance indicators, making the control system more stable and reliable.

• Using active power factor correction technology (PFC), the input power factor is close to 1, which greatly reduces the pollution to the mains grid.

• Ultra-wide input voltage range, the input voltage can be as low as 208V without switching to battery power supply.

• Automatically recognize and adapt to the 50/60Hz power system, can be connected to various fuel generators and can work stably.

• With LCD+LED real-time display, users can intuitively understand the UPS operating status.

• Self-diagnostic function at startup, which can detect the hidden failure of the UPS in time.

• With AC input over-voltage and under-voltage protection, output overload protection, short-circuit protection, temperature protection, battery under-voltage warning protection and battery over-charge protection, etc.

• The efficiency of the whole machine is as high as 94.5%, which reduces the power loss of the UPS and saves the user’s use cost.

• The standard RS232 communication interface and an SNMP card (optional) can be installed to realize the UPS remote monitoring function.

• When there is no utility power, you can directly use the battery to cold start.

• With input phase sequence protection function, the phase sequence cannot be turned on when the phase sequence is reversed.

Specification:

Model EH9315-20KS EH9315-30KS EH9315-40KS
Rated Capacity 20KVA/18KW 30KVA/27KW 40KVA/32KW
Input
AC Input Connection Type 3W+N+PE
Rated Input Voltage AC 380V/400V/415V
Voltage Range AC 208V~478V
Frequency Range 45-55Hz at50Hz/54-66Hz at60Hz (Auto Sensing)
Input Power Factor ≥0.99
Input current Harmonics ≤3% (100% Non-linear Load)
Bypass Range Bypass protection voltage upper limit: 220V: +25% (optional: +10%, +15%,+25%)

230V: +20% (optional +10%, +15%)

240V: +15% (optional +10%)

Bypass protection voltage lower limit: -45% (optional -20%, -30%)
Bypass bypass protection range: ±10%
Output
AC Output Connection Type L+N+PE
Output Voltage 220/230/240VAC
Output Power Factor 0.8/0.9
Output Accuracy ±1%
Output Frequency Online mode: follow the mains frequency, battery mode: 50/60Hz±0.2%
Output Harmonic Distortion ≤ 2% linear load; ≤ 5% non-linear load
Battery
Number Of Batteries Optional: DC±192V/204V/216V/228V/240V (±16/17/18/19/20 pcs)Default: DC±192V
Recharging Current 10A max
Other
Switching Time Mains mode to bypass mode: 0ms; Mains mode to battery mode: 0ms
Normal mode (full load) ≥Efficiency 94.5%
Communication Interface RS232, RS485, SNMP card (optional), relay card (optional)
Protection
Overload Protection Load ≤ 110%, 60min; ≤ 125%, 10min; ≤ 150%, 1min; ≥ 150%, immediately transfer to bypass
Over Temperature Protection Normal mode: switch to bypass mode; battery mode: turn off the output immediately
Emergency Shutdown (EPO) Turn off output immediately
Maintenance Bypass Standard maintenance bypass switch
Working Environment
Operating Temperature 0~40℃
Storage Temperature -25~55℃ (Battery: 0~40℃ )
Relative Humidity 0%~95% (no condensation)
Altitude Altitude <1500m, when it exceeds 1500m, use derating according to GB/T 3859.2
Physics Characteristic
Overall Volume (D*W*H) (mm) 690*250*734
Net Weight (kg) 46 47 48
]]>
EH9335 Rack Mount Series (10-40KVA) https://www.mustpower.com/product/eh9335-rack-mount-series-10-40kva/ Wed, 06 Mar 2024 11:29:47 +0000 https://www.mustpower.com/?post_type=product&p=23906 High Frequency Three Phase(3/3) Rack Mount Online UPS EH9335 is new generation of high-frequency online UPS developed, which use with Advanced DSP digital control technology. Effectively improve product performance and system reliability, and achieve higher power density, with features such as small size, light weight, and high work efficiency, etc. This series of UPS can solve almost all power problems, such as power outage, city power high voltage, city power low voltage, voltage drop, amplitude reduction, Power problems such as high voltage pulses, voltage fluctuations, surge voltages, harmonic distortion, clutter interference, and frequency fluctuations to provide the best power environment for the load. Adopt 3U rack structure to be installed easily.]]> Performance:

• Double conversion online design, 0ms exchange output, single input and single output voltage.

• With DSP digital control technology, Excellent performance index, the control system more stable and reliable.

• With active power factor correction technique (PFC), Input power factor close to 1, greatly reducing the pollution of the electricity grid.

• Ultra-wide input voltage range.

• Input frequency range of 40~70Hz, to ensure access to a variety of fuel generators can work.

• LCD + LED using real-time display, the user can intuitively understand the operating state of the UPS.

• Has turned self-diagnostic function, can detect hidden faults of UPS.

• With AC input over-voltage and under-voltage protection, output overload protection, short-circuit protection, temperature protection, battery under-voltage warning protection and battery overcharge protection, etc.

• Overall efficiency 94.5% reduction in power loss of UPS, saving the user’s cost.

• When there is no utility power, it can directly use the battery to start working.

• When the utility power is restored, the UPS can automatically turn on and charge the battery at the same time to realize the unattended function.

• When the electricity is interrupted, UPS will discharge untill power off during battery mode.

• The standard RS232 communication interface enables multi-functional and multi-purpose monitoring and management operations between the UPS and

computer through a computer window, and an SNMP card (optional) can be installed to realize the UPS remote monitoring function.

Specification:

Model EH9335- 10KRS EH9335- 15KRS EH9335- 20KRS EH9335- 30KRS EH9335- 40KRS
RatedPower 10KAVA/9KW 15KVA/13.5KW 20KVA/18KW 30KVA/27KW 40KVA/32KW
Input
Input format Three-phase four- line+ground
Rated input voltage AC 380V/400V/415V
Voltage range AC 208V~478V
Frequency range 45-55Hz at50Hz/54-66Hz at60Hz (Auto sensing)
Input power factor ≥0.99
Input current harmonic ≤3% (100% Nonlinear load)
Bypass range Bypass protection voltage upper limit: 220V: +25% (Optional +10%, +15%, +25%)

230V: +20% (Optional+ 10%, +15%)

240V: +15% (Optional+10%)

Bypass protection voltage lower limit: -45% (Optional -20%-30%)
Bypass frequency protection range: ±10%
Output
Output Three-phase four-line + ground
Output Voltage AC 380V/400V/415V
Output power factor 0.8/0.9
Output range ±1%
Output frequency Online Mode: following utility electricity frequency, battery mode: 50/60Hz±0.2%
Load peak ratio 3:1
Output harmonic distortion ≤ 2% Linear Load ≤ 5% Nonlinear Load
Battery
Battery Number Optional: DC±192V/204V/216V/228V/240V (±16/17/18/19/20 pcs) Default: DC±192V
Charging Current 10A max
Protection
Overload Protection Loading ≤ 110%, 60min; ≤ 125%, 10min; ≤ 150%, 1min; ≥ 150% change to bypass
Over temperature Normal mode: change to bypass mode; Battery mode: stop output
Emergency shutdown (EPO) Stop output
Other
Change-over time Utility mode to bypass mode: 0ms (tracking); utility mode to battery mode: 0ms
Normal mode (Full load) ≥efficiency 94.5%
Communication Connection RS232,RS485,SNMP (Optional)
ECO mode support
Self-test function support
Parallel function Max 4pcs
Working environment
Working temperature 0~40℃
Storage Temperature -25~55℃ (batteries: 0~40℃ )
Relative humidity 0%~95% (no condensation)
Altitude < 1500m, when above 1500m, when above 1500m, derate according to GB/T 3859.2
Physical Characteristics
Size (D*W*H) (mm) 580*443*131
Net Weight (kg) 32 32.5 33 33.5 34
]]>
EH9335 Three Phase Series (10-40KVA) https://www.mustpower.com/product/eh9335-three-phase-series-10-40kva/ Wed, 06 Mar 2024 11:29:47 +0000 https://www.mustpower.com/?post_type=product&p=23907 High Frequency Three Phase(3/3) Online UPS The EH9335 series of 3/3 Phase Online UPS adopts double-change online design, with input power factor correction (PFC), which makes the input power factor as high as 0.99. It has a high energy density ratio, which greatly reduces its own volume and floor space of the computer room. Using digital control, the system is highly stable, with selfprotection and fault diagnosis capabilities. This series of UPS can better solve power supply problems such as instantaneous voltage drop, damping oscillation, high voltage pulse, surge voltage, harmonic distortion, clutter interference, and frequency fluctuation for users.
Model Certification & Standards
EH9335-10K, 20K, 30K, 40K EN IEC62040-1:2019, IEC62040-1:2017, EN62040-2:2018, IEC62040-2:2016
]]>
Performance:

• Double conversion high frequency online design.

• Using digital control, the system is more stable.

• With input power factor correction (PFC), the input power factor is 0.99.

• The number of battery cells can be set according to user needs: ±16/17/18/19/20 cells.

• With parallel interface, 4 units can be paralleled, and battery packs can be shared in parallel.

• The charging current can be set, and the three-stage charging management of constant voltage, constant current, and floating charge can be automatically switched.

• With LCD and LED dual display, users can intuitively understand the working status and parameters of the UPS.

• With a maintenance bypass switch, which can be maintained when the power is uninterrupted.

• The output load capacity is strong, which can adapt to the unbalanced three-phase load.

• With RS232 communication interface and SNMP (optional) card.

• With emergency shutdown (EPO) button interface, in an emergency, press the EPO button to emergency shutdown.

Specification:

Model EH9335- 10K EH9335- 20K EH9335- 30K EH9335- 40K
Rated capacity 10KVA/9KW 20KVA/18KW 30KVA/27KW 40KVA/32KW
Input
Input format Three-phase four-line + ground
Rated input voltage AC 380V/400V/415V
Voltage range AC 208V~478V
Frequency range 45-55Hz at50Hz / 54-66Hz at60Hz (Auto)
Input power factor ≥0.99
Input current harmonic ≤3% (100% Nonlinear load)
Bypass range Bypass protection voltage upper limit: 220V: +25% (Optional +10%, +15%, +25%)230V: +20% (Optional+ 10%, +15%)240V: +15% (Optional+10%)
Bypass protection voltage lower limit: -45% (Optional -20%-30%)
Bypass frequency protection range: ±10%
Outout
Output format Three-phase four-line + ground
Rated output voltage AC 380V / 400V / 415V
Output power factor 0.8 / 0.9
Output accuracy ±1%
Output frequency Online mode: Follow the utility frequency; Battery Mode: 50/60Hz±0.2%
Output current harmonic ≤ 2% Linear Load ≤ 5% Nonlinear Load
Battery
Battery number 7Ah*40pcs 7Ah*40pcs 9Ah*40pcs 9Ah*40pcs
Charging Current 5A max
Protection
Overload protection Load 110%, 60min;  ≤ 125%, 10min;  ≤ 150%, 1min; ≥ 150% Transfer to bypass immediately
Over Temperature Protection Normal mode: switch to bypass mode; battery mode: shut down output immediately
Emergency shutdown (EPO) Shut down output immediately
Maintenance bypass Standard maintenance bypass switch
Other
Switching time Utility mode to bypass mode: 0ms; utility mode to battery mode: 0ms
Normal mode (full load) ≥efficiency 94.5%
Communication interface RS232,RS485,SNMP Card (optional), electric relay card (optional)
Energy Saving Mode (ECO) Support
Self-check function Support
Parallel function Support up to 4 units in parallel
Executive standard YD/T1095-2018
Operating Environment
Operating temperature 0~40℃
Storage temperature -25~55℃ (batteries: 0~40℃ )
Operating environment humidity 0%~95% (no condensation)
Altitude < 1500m, when above 1500m, when above 1500m, derate according to GB/T 3859.2
Physical characteristi
Size (D*W*H) (mm) 775*335*978
Net Weight (kg) 164 165 166 167
]]>
EH9335 Three Phase Series (10-80KVA) https://www.mustpower.com/product/eh9335-three-phase-series-10-80kva/ Wed, 06 Mar 2024 11:29:47 +0000 https://www.mustpower.com/?post_type=product&p=23908 High Frequency Three Phase(3/3) Online UPS The EH9335 series of 3/3 Phase Online UPS adopts double-change online design, with input power factor correction (PFC), which makes the input power factor as high as 0.99. It has a high energy density ratio, which greatly reduces its own volume and floor space of the computer room. Using digital control, the system is highly stable, with selfprotection and fault diagnosis capabilities. This series of UPS can better solve power supply problems such as instantaneous voltage drop, damping oscillation, high voltage pulse, surge voltage, harmonic distortion, clutter interference, and frequency fluctuation for users.
Model Certification & Standards
EH9335-10KS, 20KS, 30KS, 40KS, 60KS, 80KS EN IEC62040-1:2019, IEC62040-1:2017, EN62040-2:2018, IEC62040-2:2016
]]>
Performance:

• Double conversion high frequency online design.

• Using digital control, the system is more stable.

• With input power factor correction (PFC), the input power factor is 0.99.

• The number of battery cells can be set according to user needs: ±16/17/18/19/20 cells.

• With parallel interface, 4 units can be paralleled, and battery packs can be shared in parallel.

• The charging current can be set, and the three-stage charging management of constant voltage, constant current, and floating charge can be automatically switched.

• With LCD and LED dual display, users can intuitively understand the working status and parameters of the UPS.

• With a maintenance bypass switch, which can be maintained when the power is uninterrupted.

• The output load capacity is strong, which can adapt to the unbalanced three-phase load.

• With RS232 communication interface and SNMP (optional) card.

• With emergency shutdown (EPO) button interface, in an emergency, press the EPO button to emergency shutdown.

Specification:

Model EH9335- 10KS EH9335- 20KS EH9335- 30KS EH9335- 40KS EH9335- 60KS EH9335- 80KS
Rated capacity 10KAVA/9KW 20KVA/18KW 30KVA/27KW 40KVA/32KW 60KVA/54KW 80KVA/64KW
Input
Input format Three-phase four-line + ground
Rated input voltage AC 380V/400V/415V
Voltage range AC 208V~478V
Frequency range 45-55Hz at50Hz / 54-66Hz at60Hz (Auto)
Input power factor ≥0.99
Input current harmonic ≤3% (100% Nonlinear load)
Bypass range Bypass protection voltage upper limit: 220V: +25% (Optional +10%, +15%, +25%)230V: +20% (Optional+ 10%, +15%)240V: +15% (Optional+10%)
Bypass protection voltage lower limit: -45% (Optional -20%-30%)
Bypass frequency protection range: ±10%
Outout
Output format Three-phase four-line + ground
Rated output voltage AC 380V / 400V / 415V
Output power factor 0.8 / 0.9
Output accuracy ±1%
Output frequency Online mode: Follow the utility frequency; Battery Mode: 50/60Hz±0.2%
Output current harmonic ≤ 2% Linear Load ≤ 5% Nonlinear Load
Battery
Battery number Optional: DC±192V/204V/216V/228V/240V (±16/17/18/19/20 pcs) default: DC±192V
Charging Current 10A max 20A max
Protection
Overload protection Load 110%, 60min;  ≤ 125%, 10min;  ≤ 150%, 1min; ≥ 150% Transfer to bypass immediately
Over Temperature Protection Normal mode: switch to bypass mode; battery mode: shut down output immediately
Emergency shutdown (EPO) Shut down output immediately
Maintenance bypass Standard maintenance bypass switch
Other
Switching time Utility mode to bypass mode: 0ms; utility mode to battery mode: 0ms
Normal mode (full load) ≥efficiency 94.5%
Communication interface RS232,RS485,SNMP Card (optional), electric relay card (optional)
Energy Saving Mode (ECO) Support
Self-check function Support
Parallel function Support up to 4 units in parallel
Executive standard YD/T1095-2018
Operating Environment
Operating temperature 0~40℃
Storage temperature -25~55℃ (batteries: 0~40℃ )
Operating environment humidity 0%~95% (no condensation)
Altitude < 1500m, when above 1500m, when above 1500m, derate according to GB/T 3859.2
Physical characteristi
Size (D*W*H) (mm) 690*250*734 775*335*978
Net Weight (kg) 50 50 51 52 89 90
]]>
EH5000 Three Phase Series (10-20KVA) https://www.mustpower.com/product/eh5000-three-phase-series-10-20kva/ Wed, 06 Mar 2024 11:29:46 +0000 https://www.mustpower.com/?post_type=product&p=23904 High Frequency Three Phase(3/1) Online UPS The EH5000 series is a new generation of high-frequency online UPS developed with advanced DSP digitization control technology, which effectively improves product performance and system reliability, with small size, light weight, and workmanship high efficiency. Effectively solves power outages, high-voltage mains, low-voltage mains, instantaneous voltage drops, Power problems such as ringing, high voltage pulses, surge voltage, harmonic distortion, clutter, frequency fluctuations, etc. Provide the best power environment for the load.]]> Performance:

• Double conversion online design, output zero transfer time.

• Adopt DSP digital control, excellent performance indicators, make the control system more stable and reliable.

• Using active power factor correction (PFC), the input power is close to 1, large reduced pollution to the mains grid.

• Ultra-wide input voltage range, input voltage up to 210V without switch to battery power.

• Automatically recognize and adapt to 50/60Hz power system, can access various fuel generators can work stably.

• With LCD+LED real-time display, users can intuitively understand the UPS operating status.

• With self-diagnosis function, it can discover hidden faults of UPS in time.

• N+1 parallel redundant design, which can realize 3 parallel connections, greatly improving system reliability

• With AC input over-voltage, under-voltage protection, output overload protection, short circuit protection, temperature protection, battery under-voltage warning protection and battery overcharge protection.

• The machine efficiency is up to 90%, reducing the power loss of the UPS and saving user’s cost.

• Standard RS232 communication interface allows the UPS to communicate with the computer through the computer window enables versatile, versatile monitoring and management operations and installs an SNMP card (Optional) Implement UPS remote monitoring.

• If there is no utility, you can use the battery to start cold.

• With input phase sequence protection, phase sequence can not be turned on.

• When the utility is interrupted, the UPS is discharged to the battery in battery mode; when the city power is restored, the UPS can be powered on automatically and the battery is charged for unattended operation.

Specification:

Model 3H10KS 3H15KS 3H20KS
Rated Capacity 10KVA/8KW 15KVA/12KW 20KVA/16KW
Input
Voltage Range 210-475VAC
Frequency range 46-54Hz/56-64Hz 50/60Hz (Auto)
Phase 3phase
Distortion <5%
Power factor ≥ 0.99
Generator Input Support
Output
Voltage 208VAC / 220VAC / 230VAC / 240VAC
Voltage Range 220VAC±1%
Frequency (same as frequency mode) 46-54Hz / 56-64Hz
Frequency (battery mode) 50±0.5Hz / 60Hz±0.5Hz
Crest ratio 3:1
Harmonic distortion ≤ 2%THD( (Linear load )
≤ 5%THD( (Nonlinear load)
Output Waveform Pure sine wave
Socket Terminal block
Overload
Line mode 105%-125%, 1min; 125%-135%, 30s; >135%,0.5s
Battery mode Load ≥ 105 % 30s
Efficiency
Charge mode 90%
Battery mode 90%
Utility priority mode 97%
Battery
Battery type Depending on the capacity of the external battery
Battery number 16/20 pcs
Equipment time ( full load ) Depending on the capacity of the external battery
Charge time (90%)
Charge current ( max) 4A
Rated charging voltage 218.4 / 273VDC
Temperature test Yes
Transfer time
Utility mode to battery mod 0ms
Inverter mode to bypass mode 0ms
Other
Utility priority mode Support
Normal mode (constant voltage constant frequency) Support
Parallel redundancy Three Sets( Max)
LCD display Load / Battery / Input / Output / Operating Mode
Beep sound
Battery mode beep every 4 seconds
Low electricity beep every second
Overload beep 2 every second
Malfunction Continuous beeping
Mechanical Specifications
Dimension (D*W*H)mm 248*500*616
Net weight (kg) 27 35 35
Environment
Operating environment 0~40 ℃
Relative humidity 20~90%( No condensation )
Noise intensity <55db@1Meter <60db@1Meter
Interface
Micro RS-232 Support Windows,Linux,Sun Solaris,IBM Aix,Compaq True64,SGIRIX, FreeBSD, HP-UX and MAC
USB (optional) Windows family & MAC
Slot (optional) SNMP / AS400 Relay car / RS485
EPO (optional) Support emergency shutdown
]]>
EH5500 Series (6-10KVA) https://www.mustpower.com/product/eh5500-series-6-10kva/ Wed, 06 Mar 2024 11:29:42 +0000 https://www.mustpower.com/?post_type=product&p=23895 High Frequency Single Phase Online UPS The EH5500 series is a new type high-frequency online UPS. Adopts advanced DSP digital control technology to effectively improve product performance and system reliability, and higher power density small size, light weight and high work efficiency. Effectively solve power problems such as power cut-off, Grid over voltage / low voltage, voltage instantaneous drop, amplitude reduction, high voltage pulse, surge voltage, harmonic distortion, clutter interference, frequency fluctuation and provide best power for load.
Model Certification & Standards
EH5500 H6K/H6KS, EH5500 H10K/H10KS EN IEC62040-1:2019, IEC62040-1:2017, EN62040-2:2018
EH5500 H6K/H6KS, EH5500 H10K/H10KS EN IEC62368-1:2021
]]>
Performance:

• With double conversion online design, zero output transfer time.

• Adopt DSP digital control, excellent performance indicators, more steady and reliable.

• Adopt active power factor correction technology (PFC), the input power factor is 1, can reduced the pollution to the grid, to energy saving and reducing system investment cost.

• Ultra-wide input voltage range , input voltages available 110V instead of turn to battery power.

• With LCD+LED real-time display, UPS operating available for Detection

• With self- detection function, can detect hidden faults of UPS

• Cold start by battery without grid Input.

• Input frequency range 40~70Hz, support various fuel generators

• With AC input over voltage, low voltage protection, output overload protection, short circuit protection, temperature protection, battery low voltage warning protectionand battery overcharge protection.

• Output power factor 1.0 for your option. max efficiency reach 95%, reduce loss of UPS.

• With input neutral and live line detection function, avoid the reverse connection of UPS utility input

• When utility cut-off, the UPS discharge battery in the battery mode; when the city power is recovery ,UPS turn on automatically,and charge battery at the same time, asunattended function.

• Standard RS232 communication outlet ,connect UPS and computer to realize multifunctional and multi-purpose monitoring and management operations, available SNMP card (optional) to UPS remote monitoring function.

• With 3-5 minutes can work when on full loads.

Specification:

MODEL H6K H6KS H10K H10KS
Capacity
Rated Capacity 6KVA/6KW 6KVA/6KW 10KVA/10KW 10KVA/10KW
PF 1.0 1.0 1.0 1.0
Input
Input format L+N+PE
Rated input voltage 208/220/230/240VAC
Voltage range 110~300VAC
Frequency range 50/60±6Hz (Default), ±10Hz (Settable)
Input power factor ≥0.99
Input total harmonic distortion ≤4% inear load
Output
Output format L+N+PE
Output voltage 208/220/230/240VAC
Output accuracy ±1%
Output frequency For on-line mode: follow current frequency, battery mode: 50 / 60Hz±0.1%
Output harmonic distortion ≤ 2% linear load; ≤ 4% nonlinear load (PF=0.7)
Overload capacity AC Mode:

30min@102%~110% Load;

10min@110%~130% Load;

30s@130%~150% Load;

200ms@>150% Load

Battery Mode:

10min@102%~110% Load;

1min@110%~130% Load;

10s@130%~150% Load;

200ms@>150% Load

Switching time
Switch to battery mode 0ms
Switch to bypass 4ms
AC priority mode Support
Efficiency
AC Mode (Full Load) Peak efficiency 95.5%,Full load efficiency 95%
Battery Mode (Full Load) Peak efficiency 95.3%,Full load efficiency 94.8% (20pcs Battery)
Battery
Battery type Lead Acid Battery
Battery number 7Ah*16 16/18/20 (adjustable) 16 (default ) 9Ah*16 16/18/20 (adjustable) 16 (default )
Chaging current 1A (default) 1-12A (adjustable) 1A (default) 1-12A (adjustable)
Charging mode Two-stage/three-stage charging
Display
LCD 2×8 PIN/Pitch 2.54mm, support 128-bit segment code, up to 4 buttons + 4 LEDs, can display operating mode / load / input / output, etc.
Interface
RS-232 Support: Windows 2000/2003/XP/Vista/2008/7/Linux/Unix and MAC
USB Windows Family & MAC
EPO Support
Intelligent slot (Optional) SNMP/AS400 Relay Card/RS485
Maintenance bypass switch (Optional) Support
Environmental parameters
Operating ambient temperature 0~40℃
Operating environment humidity 20%~95%(no condensation)
Storage temperature -15~60℃ (batteries: 0~40℃ )
Altitude The elevation should not exceed 1000m, 1000m or above, up to 4000 m, reference IEC62040
Noise ≤ 45db
Mechanical Specifications
Dimensions (D*W*H) (mm) 500*250*615 455*190*330 500*250*615 455*190*330
Net weight (kg) 53 12 55 12
]]>
EH5500 Split Type Series (6-10KVA) https://www.mustpower.com/product/eh5500-split-type-series-6-10kva/ Wed, 06 Mar 2024 11:29:42 +0000 https://www.mustpower.com/?post_type=product&p=23896 High Frequency Single Phase Online UPS The EH5500 series is a new type high-frequency online UPS. Adopts advanced DSP digital control technology to effectively improve product performance and system reliability, and higher power density small size, light weight and high work efficiency. Effectively solve power problems such as power cut-off, Grid over voltage / low voltage, voltage instantaneous drop, amplitude reduction, high voltage pulse, surge voltage, harmonic distortion, clutter interference, frequency fluctuation and provide best power for load.]]> Performance:

• With double conversion online design, zero output transfer time.

• Adopt DSP digital control, excellent performance indicators, more steady and reliable.

• Adopt active power factor correction technology (PFC), the input power factor is 1, can reduced the pollution to the grid, to energy saving and reducing system investment cost.

• Output voltage 208Vac/220Vac/230Vac/240Vac can be set.

• Ultra-wide input voltage range , input voltages available 110V instead of turn to battery power.

• With LCD+LED real-time display, UPS operating available for Detection.

• With self-detection function, can detect hidden faults of UPS.

• Cold start by battery without grid Input.

• Input frequency range 40~70Hz, support various fuel generators.

• With AC input over voltage, low voltage protection, output overload protection, short circuit protection, temperature protection, battery low voltage warning protectionand battery overcharge protection.

• Output power factor 1.0 for your option. max efficiency reach 95%, reduce loss of UPS.

• Standard RS232 communication outlet ,connect UPS and computer to realize multifunctional and multi-purpose monitoring and management operations, available SNMP card (optional) to UPS remote monitoring function

• The split type model can directly replace the entire built-in battery pack, avoiding safety accidents caused by battery replacement.

Specification:

MODEL EH55 6KS EH55 6K Split Type EH55 10KS EH55 10K Split Type
Rated Capacity 6KVA/6KW 10KVA/10KW
Input
Input format L+N+PE
Rated input voltage 208/220/230/240VAC
Voltage range 110~300VAC
Frequency range 50/60±6Hz (Default), ±10Hz (Settable)
Input power factor ≥0.99
Input total harmonic distortion ≤4% inear load; ≤6% non-linear load (PF=0.7)
Outputm
Output format L+N+PE
Output voltage 208/220/230/240VAC
Output accuracy ±1%
Output frequency For on-line mode: follow current frequency, battery mode: 50 / 60Hz±0.1%
Output harmonic distortion ≤ 2% linear load; ≤ 4% nonlinear load (PF=0.7)
Overload capacity AC Mode:

30min@102%~110% Load;

10min@110%~130% Load;

30s@130%~150% Load;

200ms@>150% Load

Battery Mode:

10min@102%~110% Load;

1min@110%~130% Load;

10s@130%~150% Load;

200ms@>150% Load

Switching time
Switch to battery mode 0ms
Switch to bypass 4ms
AC priority mode Support
Efficiency
AC Mode (Full Load) Peak efficiency 95.5%, Full load efficiency 95%
Battery Mode (Full Load) Peak efficiency 95.3%, Full load efficiency 94.8% (20pcs Battery)
Battery
Battery type Lead Acid Battery
Battery number 16/18/20 (adjustable) 16 (default ) 7Ah*16 16/18/20 (adjustable) 16 (default ) 9Ah*16
Chaging current 1-12A (adjustable) 1A (default) 1-12A (adjustable) 1A (adjustable)
Inside batteries / Separable / Separable
Charging mode Two-stage/three-stage charging
Display
LCD 2×8 PIN/Pitch 2.54mm, support 128-bit segment code, up to 4 buttons + 4 LEDs, can display operating mode / load / input / output, etc.
Interface
RS-232 Support: Windows 2000/2003/XP/Vista/2008/7/Linux/Unix and MAC
USB Windows Family & MAC
EPO Support
Intelligent slot (Optional) SNMP/AS400 Relay Card/RS485
Maintenance bypass switch (Optional) Support
Environmental parameters
Operating ambient temperature 0~40℃
Operating environment humidity 20%~95%(no condensation)
Storage temperature -15~60℃ (batteries: 0~40℃ )
Altitude The elevation should not exceed 1000m, 1000m or above, up to 4000 m, reference IEC62040
Noise ≤50db
Mechanical Specifications
Dimensions (D*W*H) (mm) 460*200*360 460*200*700 460*200*360 460*200*770
Net weight (kg) 13 62 13 64
]]>
EH5500 TLV Series (AC:110/220V 6-10KVA) https://www.mustpower.com/product/eh5500-tlv-series-ac110-220v-6-10kva/ Wed, 06 Mar 2024 11:29:42 +0000 https://www.mustpower.com/?post_type=product&p=23897 High Frequency Single Phase Online UPS The EH5500 series is a new type high-frequency online UPS. Adopts advanced DSP digital control technology to effectively improve product performance and system reliability, and higher power density small size, light weight and high work efficiency. Effectively solve power problems such as power cut-off, Grid over voltage / low voltage, voltage instantaneous drop, amplitude reduction, high voltage pulse, surge voltage, harmonic distortion, clutter interference, frequency fluctuation and provide best power for load.]]> Performance:

• With double conversion online design, zero output transfer time.

• Adopt DSP digital control, excellent performance indicators, more steady and reliable.

• Adopt active power factor correction technology (PFC), the input power factor is 1, can reduced the pollution to the grid, to energy saving and reducing system investment cost.

• Output voltage 100Vac/110Vac/115Vac/120Vac/208Vac/220Vac/230Vac/240Vac can be set.

• Ultra-wide input voltage range , input voltages available 110V instead of turn to battery power.

• With LCD+LED real-time display, UPS operating available for Detection.

• With self-detection function, can detect hidden faults of UPS.

• Cold start by battery without grid Input.

• Input frequency range 40~70Hz, support various fuel generators.

• With AC input over voltage, low voltage protection, output overload protection, short circuit protection, temperature protection, battery low voltage warning protectionand battery overcharge protection.

• Output power factor 1.0 for your option. max efficiency reach 95%, reduce loss of UPS.

• Standard RS232 communication outlet ,connect UPS and computer to realize multifunctional and multi-purpose monitoring and management operations, available SNMP card (optional) to UPS remote monitoring function.

• The split type model can directly replace the entire built-in battery pack, avoiding safety accidents caused by battery replacement.

Specification:

MODEL EH55 TLV 6K EH55 TLV 6KS EH55 TLV 10K EH55 TLV 10KS
Rated Capacity 6KVA/6KW 10KVA/10KW
Input
Input format L+N+PE
Rated input voltage 220/230/240VAC
Voltage range 110~300VAC
Frequency range 50/60±6Hz (Default), ±10Hz (Settable)
Input power factor ≥0.99
Input total harmonic distortion ≤4% inear load
Output
Output format L+N+PE
Output voltage 100/110/115/120VAC; 208/220/230/240VAC
Output accuracy ±1%
Output frequency For on-line mode: follow current frequency, battery mode: 50 / 60Hz±0.1%
Output harmonic distortion ≤ 2% linear load; ≤ 5% nonlinear load (PF=0.7)
Overload capacity

AC Mode:

30min@102%~110% Load

10min@110%~130% Load

30s@130%~150% Load

200ms@>150% Load

Battery Mode:

1min@102%~110% Load

10s@110%~130% Load

3s@130%~150% Load

200ms@>150% Load

Switching time
Switch to battery mode 0ms
Switch to bypass 4ms
AC priority mode Support
Efficiency
AC Mode (Full Load) Peak efficiency 95.5%, Full load efficiency 94%
Battery Mode (Full Load) Peak efficiency 94.5%, Full load efficiency 94.3% (20pcs Battery)
Battery
Battery type Lead Acid Battery
Battery number 7Ah*16 16/18/20 (adjustable) 16 (default ) 7Ah*16 16/18/20 (adjustable) 16 (default )
Chaging current 1A (default) 1-12A adjustable (default 5A)) 1A (default) 1-12A adjustable (default 5A))
Charging mode Two-stage/three-stage charging
Display
LCD 2×8 PIN/Pitch 2.54mm, support 128-bit segment code, up to 4 buttons + 4 LEDs, can display operating mode / load / input / output, etc.
Interface
RS-232 Support: Windows 2000/2003/XP/Vista/2008/7/Linux/Unix and MAC
USB Windows Family & MAC
EPO Support
Intelligent slot (Optional) SNMP/AS400 Relay Card/RS485
Maintenance bypass switch (Optional) Support
Environmental parameters
Operating ambient temperature 0~40℃
Operating environment humidity 20%~95%(no condensation)
Storage temperature -15~60℃ (batteries: 0~40℃ )
Altitude The elevation should not exceed 1000m, 1000m or above, up to 4000 m, reference IEC62040
Noise ≤50db
Mechanical Specifications
Dimensions (D*W*H) (mm) 500*250*610 500*250*850 500*250*610 500*250*850
Net weight (kg) 93 59 102 60.5
]]>
EH5500 Rack Mount Series (1-3KVA) https://www.mustpower.com/product/eh5500-rack-mount-series-1-3kva/ Wed, 06 Mar 2024 11:29:42 +0000 https://www.mustpower.com/?post_type=product&p=23898 High Frequency Single Phase Online UPS The EH5500 series is a new type high-frequency online UPS. Adopts advanced DSP digital control technology to effectively improve product performance and system reliability, and higher power density small size, light weight and high work efficiency. Effectively solve power problems such as power cut-off, Grid over voltage/low voltage, voltage instantaneous drop, amplitude reduction, high voltage pulse, surge voltage, harmonic distortion, clutter interference, frequency fluctuation and provide best power for load. We adopt standard 2U rack structure.
Model Certification & Standards
EH5500 H1KR/H1KRS, EH5500 H2KR/H2KRS, EH5500 H3KR/H3KRS EN IEC62040-1:2019, IEC62040-1:2017, EN62040-2:2018
]]>
Performance:

• With double conversion online design, zero output transfer time. Single phase input and output voltage.

• Adopt DSP digital control, excellent performance indicators, more steady and reliable.

• Adopt active power factor correction technology (PFC), the input power factor is 1, can reduced the pollution to the grid, To energy saving and reducing system investment.

• Ultra-wide input voltage range.

• Input frequency range 40~70Hz, support various fuel generators.

• With LCD+LED real-time display, users can intuitively understand the UPS operating status.

• With self- detection function, can detect hidden faults of UPS in time.

• With AC input over voltage, low voltage protection, output overload protection, short circuit protection, temperature protection, battery low voltage warning protection and battery overcharge protection.

• The efficiency of the whole UPS is as high as 95.5%, which reduces the power loss of it and saves the user’s use cost.

• When there is no mains power, you can directly use the battery to cold start.

• With input neutral and live line detection function, avoid the reverse connection of UPS utility input

• When utility cut-off, the UPS discharge battery in the battery mode; when the city power is recovery ,UPS turn on automatically,and charge battery at the same time, as unattended function.

• Standard RS232 communication outlet ,connect UPS and computer to realize multifunctional and multi-purpose monitoring and management operations, available SNMP card (optional) to UPS remote monitoring function.

Specification:

Model H1KR H1KRS H2KR H2KRS H3KR H3KRS
Rated Capacity 1KVA/1KW 2KVA/2KW 3KVA/3KW
Input
Input connection type L+N+PE
Rated input voltage 208/220/230/240VAC
Voltage range 110-300VAC
Frequency rage 50/60+HZ (default), ±10HZ (can be set)
Input power factor ≥ 0.99
Input THD ≤ 4% % linear load
Output
Output connection type L+N+PE
Output voltage 208/220/230/240VAC
Output accuracy ±1%
Output frequency Mains  mode:same as AC frequency, battery mode : 50/60HZ+-0.1%
Output THD ≤2% linear load, ≤ 4% Non-linear load (PF=0.7)
Output power factor 1
Overload Capacity AC mode :

30min@102%~110% Load;

10min@110%~130% Load;

30s@130%~150% Load;

200ms@>150% Load

Battery mode :

10min@102%~110% Load;

1min@110%~130% Load;

10s@130%~150% Load;

200ms@>150% Load

Transfer time
AC mode switch to battery mode 0ms
mains inverter mode switch to bypass mode 4ms
AC priority mode Support
Overall Efficiency
AC Mode (Full Load) 94.5%@220VAC 95.5%@220VAC 95.5%@220VAC
Battery Mode (Full Load) 87.5% @24VDC 88.5% @36VDC 89.5% @48VDC 91.5% @72VDC 91.5% @72VDC 91.5% @96VDC
Battery
Battery type Lead Acid Battery
Number of batteries 7Ah*2/3 / 7Ah*4 / 7Ah*6 /
Battery  Charge Current 1KR-3KR:1A (default); 1-2A (can be set) 1KRS-3KRS:5A (default);  1-12A (can be set)
Charging Mode Two-stage/three-stage charging
Display
LCD 2×8 PIN/Pitch 2.54mm, support 128-bit segment code, up to 4 buttons + 4 LEDs, can display operating mode / load / input / output, etc
Interface
RS-232 Support: Windwos 2000/2003/XP/Vista/2008/7/Linux/Unix and MAC
USB Windows Famlly & MAC
Intelligent slot (Optional) SNMP/AS400 Relay Card/RS485
Environmental parameters
Operating ambient temperature 0~40℃
Operating environment humidity 20%~95% (No condensation)
Storage temperature -15~60℃ ( Battery : 0~40℃ )
Altitude The altitude should not exceed 1000m, derating above1000m, up to  4000m (max ) , refer  IEC62040
Noise ≤45db
Mechanical Specifications
Dimensions (D*W*H) (mm) 438*420*88 438*600

*88

438*420

*88

438*600

*88

438*420

*88

Net weight (kg) 9.5/11.5 6 17 6.5 21.5 7
]]>