Off Grid Solar Inverter – Hybrid Solar Inverter & ESS Manufacturer https://www.mustpower.com Must Energy Storage System Fri, 30 May 2025 11:37:15 +0000 en-US hourly 1 https://wordpress.org/?v=6.8.2 ECO Series (2-12kW) https://www.mustpower.com/product/eco-series-2-12kw/ Fri, 30 May 2025 11:37:15 +0000 https://www.mustpower.com/?post_type=product&p=25040 ECO Series | High Frequency Solar Inverter Smart Power. Battery Optional. Solar Ready. The ECO Series is a compact and powerful multi-function solar inverter/charger that combines an inverter, MPPT solar controller, and AC battery charger in one smart unit. Designed for flexibility, it supports operation with or without batteries—ideal for residential, mobile, and light commercial solar systems. With high PV input voltages up to 500V and MPPT current up to 150A, the ECO Series helps users harvest more energy from solar panels while ensuring consistent and efficient power delivery. ]]> 🔋 Specifications
• Power range: 2000W – 12000W
• DC input voltage: 12V / 24V / 48V
• Max. PV input voltage: 400V / 450V / 500V
• MPPT solar charge current: 80A / 100A / 120A / 150A

✅ Key Features
■ Built-in MPPT solar charge controller for maximum solar efficiency
■ Supports battery-less operation – runs directly on solar and grid
■ Dual AC outputs for smart load management
■ Smart LCD settings: working modes, charge current, charge voltage, etc.
■ Lithium battery compatibility with RS485/CAN communication
■ Complete protection: overload, short circuit, deep discharge
■ Cold start function ensures startup in extreme conditions
■ Wide PV input voltage range to adapt to more solar configurations
■ Integrates solar, grid, and battery sources for seamless power switching
■ OEM customizable appearance and color available
■ Full solar system packages optional

⚡ Applications
Perfect for home backup power, solar-powered mobile systems, off-grid cabins, and hybrid setups requiring flexibility, solar efficiency, and budget-conscious performance.

MODEL ECO-2012 ECO-3624 ECO-4024 ECO-6048 ECO-6248 ECO-8048 ECO-10048 ECO-12048
Nominal Battery System Voltage 12VDC 24VDC 24VDC 48VDC 48VDC 48VDC 48VDC 48VDC
INVERTER OUTPUT
Rated Power
(Main+Second Load)
2000VA/2000W 3600VA/3600W 4000VA/4000W 6000VA/6000W 6200VA/6200W 8000VA/8000W 10000VA/10000W 12000VA/12000W
Battery Mode
(Main+Second Load)
2000VA/1600W 3000VA/3000W 3500VA/3500W 5500VA/5500W 6200VA/6200W 8000VA/8000W 10000VA/10000W
(Battery current limited)
12000VA/12000W
(Battery current limited)
Surge Power 3200W 6000W 7000W 11000W 12400W 16000W 20000W 24000W
Waveform Pure sine wave
AC Voltage Regulation
(Batt.Mode)
230VAC±5%(Setting)
Inverter Efficiency(Peak) 90~93%
Transfer Time 10ms (UPS / VDE4105) / 20ms (APL)
AC INPUT
Voltage 230VAC±5%
Selectable Voltage Range 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VED4105)
Frequency Range 50Hz / 60Hz(Auto sensing)
BATTERY
Normal voltage 12VDC 24VDC 24VDC 48VDC 48VDC 48VDC 48VDC 48VDC
Floating Charge Voltage 13.7VDC 27.4VDC 27.4VDC 54.8VDC 54.8VDC 54.8VDC 54.8VDC 54.8VDC
Overcharge Protection 15VDC 30VDC 30VDC 60VDC 60VDC 60VDC 60VDC 60VDC
SOLAR CHARGER & AC CHARGER
Maximum PV Array Open Circuit Voltage 400VDC 400VDC 450VDC 450VDC 500VDC 500VDC 500VDC 500VDC
Maximum PV Input Current 16A 18A 18A 28A 28A 18A*2 27A*2
(40A max)
27A*2
(40A max)
Charging Algorithm 3-Step (Flooded Battery, AGM / GEL / LEAD Battery), 4-Step (Li)
Maximum PV Array Power 2000W 4000W 4000W 6000W 6200W 4000W*2 5000W*2 6000W*2
PV Array MPPT Voltage Range
(Typ.)
30~320VDC 60~360VDC 120~450VDC 90~450VDC
Maximum Solar Charge Current 80A 100A 100A 100A 120A 120A 150A 150A
Maximum AC Charge Current 80A 60A 60A 100A 100A 120A 150A 150A
Maximum Charge Current 80A 100A 100A 100A 120A 120A 150A 150A
MECHANICAL SPECIFICATIONS
Machine Dimension
(W*H*D)(mm)
290*367*111 318*454*122.5 425*527*145
Package Dimension
(W*H*D)(mm)
446*187*394 544.5*200*410 631.5**257*548
N.W (kg) 6.0 7.8 8.0 9.0 10.0 17.9 18.0 18.0
G.W (kg) 7.2 9.3 9.5 10.2 11.6 20.5 20.6 20.6
OTHER
Humidity 5% to 95% Relative humidity (Non-condensing)
Operating Temperature -10°C~50°C
Storage Temperature -15°C~60°C
Communication Interface USB/WIFI/RS-485/CAN
Warranty 2 year
Anti-dust Kit none yes yes yes yes yes yes yes
CERTIFICATION & STANDARDS
CE
]]>
PV1800 PRO II Series (6.2-12kW) https://www.mustpower.com/product/pv1800-pro-ii-series-6-2-12kw/ Wed, 04 Dec 2024 06:56:16 +0000 https://www.mustpower.com/?post_type=product&p=24816 Dual Output Inverters PV1800 PRO II is a multi-function inverter/charger, combining functions of inverter, MPPT solar charger and battery charger to offer uninterruptible power support in portable size. PV1800 PRO II Series can run without battery. The Maximum PV input voltage can reach 500V and MPPT voltage range is 90~430Vdc, built-in two MPPTs solar charge controller, which can help customers make full use of solar energy.]]> ■ Dual output for smart load management
■ Smart color LCD setting (Working modes, Charge Current, Charge Voltage, etc).
■ Built-in Two MPPTs solar charge controller
■ Wide MPPT voltage range is 90~450V, the maximum PV input voltage can reach 500V
■ Can provide the power to the load without battery
■ Combining solar system, AC utility, and battery power source to supply continuous power
■ Overload, short circuit and Deep discharge protection
■ With BMS lithium battery communication function
■ With AC/PV lithium battery activation function
■ Support USB, RS485 monitoring function
■ Parallel operation up to 6 units (optional)
■ WIFI remote monitoring (optional)

MODEL PV18-6248 PRO II PV18-8048 PRO II PV18-10048 PRO II PV18-11048 PRO II PV18-12048 PRO II
Default Battery System Voltage 48VDC
INVERTER OUTPUT
Rated Power 6200VA/6200W 8000VA/8000W 10000VA/10000W 11000VA/11000W 12000VA/12000W
Surge Power 12400W 16000W 20000W 22000W 24000W
Waveform Pure sine wave
AC Voltage Regulation (Batt.Mode) 230VAC±5%(Setting)
Inverter Efficiency(Peak) 92%
Transfer Time 10ms(UPS / VDE4105) / 20ms(APL)
AC INPUT
Voltage 230VAC
Selectable Voltage Range 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VDE)
Frequency Range 50Hz / 60Hz (Auto sensing)
BATTERY
Normal voltage 48VDC
Floating Charge Voltage 54.8VDC
Overcharge Protection 60VDC
SOLAR CHARGER & AC CHARGER
Maximum PV Array Open Circuit Voltage 500VDC
Charging Algorithm 3-Step (Flooded Battery, AGM / GEL / LEAD Battery), 4-Step (Li)
Maximum PV Array Power 4000W*2 4000W*2 5000W*2 6000W*2 6000W*2
Maximum PV Input Current 18A*2 18A*2 27A*2(40A max) 27A*2(40A max) 27A*2(40A max)
PV Array MPPT Voltage Range 90~430VDC
Maximum Solar Charge Current 120A 120A 150A 150A 150A
Maximum AC Charge Current 100A 120A 150A 150A 150A
Maximum Charge Current 120A 120A 150A 150A 150A
MECHANICAL SPECIFICATIONS
Machine Dimension (W*H*D)(mm) 425*473*145 425*527*145
Package Dimension (W*H*D)(mm) / / / / /
N.W (kg) / / / / /
G.W (kg) / / / / /
OTHER
Humidity 5% to 95% Relativ Humidity (Non-condensing)
Operating Temperature Range 0°C~50°C
Storage Temperature Range -15°C~60°C
Warranty 2 year
CERTIFICATION & STANDARDS
CE-EMC+LVD (EN6100-6-3:2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)
EN IEC62368-1:2020+A11:2020
CE-LVD (IEC62109-1:2010, EN IEC62109-2:2011)
EN IEC62368-1:2018, EN IEC62109-1:2010, EN IEC62109-2:2011
]]>
PV1800 PRO II Series (4/6kW) https://www.mustpower.com/product/pv1800-pro-ii-series-4-6kw/ Wed, 04 Dec 2024 06:48:34 +0000 https://www.mustpower.com/?post_type=product&p=24811 Dual Output Solar Power Inverter PV1800 PRO II is a multi-function inverter/charger, combining functions of inverter, MPPT solar charger and battery charger to offer uninterruptible power support in portable size. PV1800 PRO II Series can run without battery. The Maximum PV array open circuit voltage can reach 500V and MPPT voltage range is 90~430V for 4KW, 120v~430V for 6KW, which Can help customers make full use of solar energy.]]> ■ Pure sine wave output
■ Smart LCD setting (Working modes, Charge Current, Charge Voltage, etc).
■ Built-in MPPT solar charge controller
■ MAX PV Array Open Circuit Voltage: 500V (450V for parallel)
■ Can provide the power to the load without battery
■ Combining solar system, AC utility, and battery power source to supply continuous power
■ Overload, short circuit and Deep discharge protection
■ Cold start function
■ Support USB, RS485 monitoring function
■ Parallel operation with up to 6 units (optional)
■ WIFI remote monitoring (optional)
■ Dual outputs for smart load management
■ Can communicate with lithium batteries

MODEL PV18-4024 PRO II PV18-6048 PRO II
Default Battery System Voltage 24VDC 48VDC
INVERTER OUTPUT
Rated Power 4000VA / 4000W 6000VA / 6000W
Surge Power 8000W 12000W
Waveform Pure sine wave
AC Voltage Regulation (Batt.Mode) 230VAC±5%(Setting)
Inverter Efficiency(Peak) 92%
Transfer Time 10ms(UPS / VDE4105) / 20ms(APL)/ < 50ms typical (For parallel operation)
AC INPUT
Voltage 230VAC
Selectable Voltage Range 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VDE)
Frequency Range 50Hz / 60Hz (Auto sensing)
BATTERY
Normal voltage 24VDC 48VDC
Floating Charge Voltage 27.4VDC 54.8VDC
Overcharge Protection 30VDC 60VDC
SOLAR CHARGER & AC CHARGER
Maximum PV Array Open Circuit Voltage 500VDC (450V for parallel)
Charging Algorithm 3-Step (Flooded Battery, AGM / GEL / LEAD Battery), 4-Step (Li)
Maximum PV Array Power 5000W 6000W
PV Array MPPT Voltage Range 90~430VDC 120~430 VDC
Maximum Solar Charge Current 100A 120A
Maximum AC Charge Current 80A 100A
Maximum Charge Current 100A 120A
MECHANICAL SPECIFICATIONS
Machine Dimension (W*H*D)(mm) 322*486*134 309*505*147
Package Dimension (W*H*D)(mm) 575*229*425 603*260*400
N.W (kg) 9.5 12.5
G.W (kg) 12 13.8
OTHER
Humidity 5% to 95% Relativ Humidity (Non-condensing)
Operating Temperature 0°C~50°C
Storage Temperature -15°C~60°C
Communication Interface USB/ WIFI
Warranty 2 year
CERTIFICATION & STANDARDS
CE-EMC+LVD (EN6100-6-3:2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)
EN IEC62368-1:2020+A11:2020
CE-LVD (IEC62109-1:2010, EN IEC62109-2:2011)
EN IEC62368-1:2018, EN IEC62109-1:2010, EN IEC62109-2:2011
]]>
PV3900 Series (8-12KW) https://www.mustpower.com/product/pv3900-series-8-12kw/ Fri, 24 May 2024 07:16:06 +0000 https://www.mustpower.com/?post_type=product&p=24292 Low Frequency Solar Inverter DC 48V | PV 250V | MPPT 100/200A PV3900 Series is a multi-function inverter ,combining functions of inverter and MPPT solar charger controller, solar charger and battery charger to offer uninterruptible power support. The comprehensive LCD display offers userconfigurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and selectable input voltage based on different applications.]]> ■ Smart LCD setting(Working modes, Charge Current, Charge voltage, etc.)
■ Built-in MPPT solar charge controller 100A/200A
■ MPPT efficiency max 98%
■ Powerful charge rate up to 200A
■ Inside BMS function
■ DC start &Automatic Self-Diagnostic Function
■ WIFI monitoring function (optional)
■ Compatible to generator
■ Parallel operation with up to 3 units

MODEL PV3900-8048 PV3900-10048 PV3900-12048
Nominal Battery System Voltage 48VDC
Stand-alone mode Yes
Parallel operation 3 units
INVERTER OUTPUT
Rated power 8KW 10KW 12KW
Surge rating 24000VA 30000VA 36000VA
Capable of starting electric motor 4HP 5HP 6HP
Waveform Pure sine wave / same as input (bypass mode)
Nominal output voltage RMS 220V/230V/240V
Inverter efficiency (peak) >88%
Line mode efficiency >95%
Power factor 1.0
Typical transfer time 10ms(max)
AC INPUT
Voltage 220V/230V/240V
Selectable voltage range 90-280 VAC (APL)
Frequency range 50Hz / 60Hz
BATTERY
Low battery voltage cutoff 40-48VDC for 48VDC mode
Low battery voltage recover 42-50VDC for 48VDC mode
High battery voltage cutoff 60VDC for 48VDC mode
High battery voltage recover 57VDC for 48VDC mode
AC CHARGER
Output voltage Depends on battery type (Supports lead-acid, gel, and lithium batteries)
Charger AC input breaker rating 100A
Overcharge protection S.D. 62.8VDC for 48VDC mode
Maximum charge current 10-140A (setting) battery terminal
BTS
Continuous output power Yes Variances in charging voltage & S.D. voltage base on the battery temperature
BYPASS & PROTECTION
Input voltage waveform Sine wave (grid or generator)
Nominal input frequency 50Hz or 60Hz
Overload protection (SMPS Load) Software + Circuit breaker
Output short circuit protection Software + Circuit breaker
Bypass breaker rating 63A
Max bypass current 80A
SOLAR CHARGER
Maximum PV charge current 100A 200A 200A
DC voltage 48V
Maximum PV array power 5000W 10000W 10000W
MPPT range @ operating voltage(VDC) 64~235VDC
Maximum PV array open circuit voltage 250VDC
Maximum efficiency >98%
Standby power consumption <2W
MECHANICAL SPECIFICATIONS
Mounting Wall mount
Packing Wooden box
Machine Dimension (W*H*D)(mm) 439*660.5*223
Package Dimension (W*H*D)(mm) 782*304*520.5
N.W(kg) 59 68 75
G.W(kg) 76 85 92
Warranty 2years
OTHER
Operating temperature range 0°C to 50°C
Storage temperature 15°C to 60°C
Audible noise 60dB MAX
Communication WiFi
Display LED+LCD
CERTIFICATION & STANDARDS
CE-LVD (IEC62109-1:2010, EN IEC62109-2:2011)
]]>
PV2900 HP Series (1-6KW) https://www.mustpower.com/product/pv2900-hp-series-1-6kw/ Wed, 24 Apr 2024 03:48:41 +0000 https://www.mustpower.com/?post_type=product&p=24155 Low Frequency Inverter 1~6KW | AC 230V | MPPT 80A | PV 245V PV2900 HP series is very economical pure sine wave solar inverter, Inbuilt with 80A MPPT charger; Solar/AC priority is configurable, when setting solar priority, solar will charge batteries as first priority, and AC can also charge batteries when solar charger current is too lower, in this way system charge is optimazed best. it enables inverter to operate with all kinds of home appliances.]]> ■ 3 Steps charging
■ Overload and short-circuit protection
■ Set charging voltage/charging current
■ Battery low voltage shutdown point can be set to 10/10.5/11/11.5/12V
■ Power-save mode
■ Set utility priority /battery priority
■ Set utility input wide/narrow voltage range
■ Inverter voltage can be set to 220V/230V/240V
■ Inverter frequency can be set to 50Hz/60Hz
■ Set utility charging on/off switch
■ Inbuilt 80A MPPT Solar Charge Controller
■ Acid or Lithium Select
■ WIFI remote monitoring (optional)
■ With BMS lithium battery communication function (CAN port)
■ Dual output for smart load management

MODEL PV29-1KW-HP PV29-1.5KW-HP PV29-2KW-HP PV29-3KW-HP PV29-4KW-HP PV29-5KW-HP PV29-6KW-HP
Nominal Battery System Voltage 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 24VDC 48VDC 24VDC 48VDC 48VDC 48VDC
INVERTER OUTPUT
Rated Power 1 KW 1.5 KW 2 KW 3 KW 4 KW 5 KW 6 KW
Surge Rating 3000VA 4500VA 6000VA 9000VA 12000VA 15000VA 18000VA
Capable Of Starting Electric Motor 1P 1P 1.5P 2P 3P
Waveform Pure sine wave / same as input (bypass mode)
Nominal Output Voltage RMS 220V / 230V / 240VAC (±10% RMS)
Output Frequency 50Hz / 60Hz ±0.3Hz
Inverter Efficiency (Peak) >88%
Line Mode Efficiency >95%
Power Factor 1.0
Typical Transfer Time 10ms(max)
Overload 100% < Load < 110% (alarm 5min then stop output and fault code 07) 110% < Load < 125% (alarm 60s then stop output and fault code 07) Load > 125% (alarm 10s then stop output and fault code 07)
AC INPUT
Voltage 230VAC
Selectable Voltage Range 155~265VAC(For personal computers)
Frequency Range 50Hz / 60Hz(Auto sensing) 40~80Hz
BATTERY
Minimum Start Voltage (10V / 10.5V / 11V / 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low Battery Voltage Alarm (10V / 10.5V / 11V / 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low Battery Voltage Cut Off 10V / 10.5V / 11V / 11.5V/ 12V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High Battery Voltage Alarm (12-14.5V)+1V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High Battery Voltage Recover (12-14.5V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Energy Saving Mode Load ≤50±20W(120V)/100±20W(220V)
CHARGER
Output Voltage Depends on battery type
Overcharge Protection S.D. 15.5VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode)
Maximum Charge Current 30A 20A 45A 25A 60A 30A 40A 20A 60A 30A 35A 40A
PAYPASS & PROTECTION
Input Voltage Waveform Sine wave (grid or generator)
Nominal Input Frequency 50Hz or 60Hz
Overload Protection (SMPS Load) Circuit breaker
Output Short Circuit Protection Circuit breaker
AC Input Breaker 1-3K/30A 4-6K/50A
SOLAR CHARGER
Maximum PV Array Power 1250W 2500W 1250W 2500W 1250W 2500W 2500W 5000W 2500W 5000W 5000W 5000W
Maximum PV Charge Current 80A±4A
DC Voltage 12V/ 24V auto work 24V/ 48V auto work
MPPT Range @ Operating Voltage 15~95VDC @ 12V/ 30~230VDC @ 24V 30~230VDC @ 24V/ 60~230VDC @ 48V
Maximum PV Array Open Circuit Voltage 245VDC
Standby Power Consumption <2W
MECHANICAL SPECIFICATIONS
Mounting Wall Mount
Dimensions (W*H*D) 274*484*174mm 274*568.5*174mm
Package Dimensions (W*H*D) 583.5*376*255mm 668.5*376*255mm
N.W (kg) / /
G.W (kg) / /
OTHER
Operating Temperature Range 0°C ~ 40°C
Storage Temperature -15°C ~ 60°C
Audible Noise 60dB MAX
Display LED+LCD
Standard Warranty 2 year
CERTIFICATION & STANDARDS
CE-EMC+LVD (EN6100-6-3:2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)
]]>
PV1800 ECO Series (1.6-6.2KW) https://www.mustpower.com/product/pv1800-eco-series-1-6-6-2kw/ Tue, 23 Apr 2024 11:41:38 +0000 https://www.mustpower.com/?post_type=product&p=24145 High Frequency Off Grid Solar Inverter 1.6~6.2KW | PV 400/450/500V | Dual output | DC 12V,24V,48V PV1800 ECO is a multi-function inverter/charger, combining functions of inverter, MPPT solar charger and battery charger to offer uninterruptible power support in portable size. PV1800 ECO Series can run without battery. The Maximum PV input voltage can reach 400V/450V/500V, which can help customers make full use of solar energy.]]> ■ Pure sine wave output
■ Smart LCD setting (Working modes, Charge Current, Charge Voltage, etc).
■ Built-in MPPT solar charge controller
■ Wide PV input voltage range
■ Can provide the power to the load without battery
■ Combining solar system, AC utility, and battery power source to supply continuous power
■ Overload, short circuit and Deep discharge protection
■ Cold start function
■ Support RS485,CAN monitoring function
■ Dual outputs for smart load management
■ Can communicate with lithium batteries (CAN port)

MODEL PV18-1612 ECO PV18-2524 ECO PV18-3024 ECO PV18-3524 ECO PV18-5548 ECO PV18-6248 ECO
Default Battery System Voltage 12VDC 24VDC 24VDC 24VDC 48VDC 48VDC
INVERTER OUTPUT
Rated Power 2000VA/1600W 2500VA/2500W 3000VA/3000W 3500VA/3500W 5500VA/5500W 6200VA/6200W
Output Channel Dual Dual Dual Dual Dual Dual
Surge Power 3200W 5000W 6000W 7000W 11000W 12400W
Waveform Pure sine wave
AC Voltage Regulation (Batt.Mode) 230VAC±5%(Setting)
Inverter Efficiency(Peak) >90%
Transfer Time Typical < 10ms , 20ms max
AC INPUT
Voltage 230VAC
Selectable Voltage Range 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VDE)
Frequency Range 50Hz / 60Hz (Auto sensing)
BATTERY
Normal voltage 12V 24VDC 24VDC 24VDC 48VDC 48VDC
Floating Charge Voltage 13.7VDC 27.4VDC 27.4VDC 27.4VDC 54.8VDC 54.8VDC
Overcharge Protection 15VDC 30VDC 30VDC 30VDC 60VDC 60VDC
SOLAR CHARGER & AC CHARGER
Maximum PV Input Voltage 400VDC 400VDC 400VDC 450VDC 450VDC 500VDC
Charging Algorithm 3-Step (Flooded Battery, AGM / GEL / LEAD Battery), 4-Step (Li)
Maximum PV Array Power 2000W 4000W 4000W 4000W 6000W 6200W
PV Array MPPT Voltage Range(Typ.) 30~320VDC 30~320VDC 30~320VDC 60~360VDC 60~360VDC 120~450VDC
PV maximum input current 16A 18A 18A 18A 28A 28A
Maximum Solar Charge Current 80A 100A 100A 100A 100A 120A
Maximum AC Charge Current 80A 60A 60A 60A 100A 100A
Maximum Charge Current 80A 100A 100A 100A 100A 120A
MECHANICAL SPECIFICATIONS
Machine Dimension (W*H*D)(mm) 290*367*111 290*367*111 290*367*111 318*367*122.5 318*454*122.5 318*428*140
Package Dimension (W*H*D)(mm) 446*394*187 446*394*187 446*394*187 446*410*200 544.5*410*210 550*400*220
N.W (kg) 6.4 6.7 6.7 7.3 9.0 10.0
G.W (kg) 7.4 7.7 7.7 8.3 10.5 11.6
OTHER
Humidity 5% to 95% Relativ Humidity (Non-condensing)
Operating Temperature 0°C~50°C
Storage Temperature -15°C -60°C
Warranty 2years
CERTIFICATION & STANDARDS
CE
]]>
PV2900 LHP Series (AC:110V 1-6KW) https://www.mustpower.com/product/pv2900-lhp-series-ac110v-1-6kw/ Tue, 23 Apr 2024 11:35:14 +0000 https://www.mustpower.com/?post_type=product&p=24140 Low Frequency Solar Inverter AC 120V | MPPT 80A | WIFI | BMS | Dual output PV2900 LHP series is very economical pure sine wave solar inverter, AC voltage 110V/120V, AC charger inbuilt, from 20A to 60A; MPPT solar charger 80A inbuilt; Solar/AC priority is configurable, when setting solar priority, solar will charge batteries as first priority, and AC can also charge batteries when solar charger current is not enough, it enables inverter to operate with all kinds of home appliances, widely selling to Latin America.]]> ■ Pure sine wave output
■ 3 Steps charging
■ Overload and short-circuit protection
■ Set charging voltage/charging current.
■ Battery low voltage shutdown point can be set to 10/10.5/11/11.5/12V
■ Power-save mode
■ Set utility priority/ Battery priority
■ Set utility input wide/narrow range
■ Inverter voltage can be set to 120V:110V/115V/120V
■ Inverter frequency can be set to 50/60Hz
■ Set utility charging on/off switch
■ 80A MPPT charger
■ Acid or Lithium Select
■ WiFi port (optional)
■ With BMS lithium battery communication function (CAN port)
■ Dual output for smart load management

MODEL PV29-1KW-LHP PV29-1.5KW-LHP PV29-2KW-LHP PV29-3KW-LHP PV29-4KW-LHP PV29-5KW-LHP PV29-6KW-LHP
Nominal Battery System Voltage 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 24VDC 48VDC 24VDC 48VDC 48VDC 48VDC
INVERTER OUTPUT
Rated Power 1 KW 1.5 KW 2 KW 3 KW 4 KW 5 KW 6 KW
Surge Rating 3000VA 4500VA 6000VA 9000VA 12000VA 15000VA 18000VA
Capable Of Starting Electric Motor 1P 1P 1.5P 2P 3P
Waveform Pure sine wave / same as input (bypass mode)
Nominal Output Voltage RMS 110V / 115V / 120VAC(±10% RMS)
Output Frequency 50Hz / 60Hz ±0.3Hz
Inverter Efficiency (Peak) >88%
Line Mode Efficiency >95%
Power Factor 1.0
Typical Transfer Time 10ms(max)
Overload 100% < Load < 110% (alarm 5min then stop output and fault code 07) 110% < Load < 125% (alarm 60s then stop output and fault code 07) Load > 125% (alarm 10s then stop output and fault code 07)
AC INPUT
Voltage 110/120VAC
Selectable Voltage Range 75~135VAC (For personal computers)
Frequency Range 50Hz / 60Hz(Auto sensing) 40~80Hz
BATTERY
Minimum Start Voltage (10V / 10.5V / 11V / 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low Battery Alarm (10V / 10.5V / 11V / 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low Battery Cut Off 10V / 10.5V / 11V / 11.5V/ 12V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High Voltage Alarm (12-14.5V)+1V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High Battery Voltage Recover (12-14.5V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Idie Consumption-Search Mode Load ≤50±20W(120V)/100±20W(220V)
CHARGER
Output Voltage Depends on battery type
Overcharge Protection S.D. 15.5VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode)
Maximum Charge Current 30A 20A 45A 25A 60A 30A 40A 20A 60A 30A 35A 40A
PAYPASS & PROTECTION
Input Voltage Waveform Sine wave (grid or generator)
Nominal Input Frequency 50Hz or 60Hz
Overload Protection (SMPS Load) Circuit breaker
Output Short Circuit Protection Circuit breaker
AC Input Breaker 1-3K/40A 4-6K/63A
SOLAR CHARGER
Maximum PV Array Power 1250W 2500W 1250W 2500W 1250W 2500W 2500W 5000W 2500W 5000W 5000W 5000W
Maximum PV Charge Current 80A±4A
DC Voltage 12V/ 24V auto work 24V/ 48V auto work
MPPT Range @ Operating Voltage 15~95VDC @ 12V/ 30~230VDC @ 24V 30~230VDC @ 24V/ 60~230VDC @ 48V
Maximum PV Array Open Circuit Voltage 245VDC
Standby Power Consumption <2W
MECHANICAL SPECIFICATIONS
Mounting Wall Mount
Machine Dimension (W*H*D)(mm) 274*484*174 274*568.5*174
Package Dimension (W*H*D)(mm) 583.5*255*376 668.5*255*376
N.W(kg) / /
G.W(kg) / /
OTHER
Operating Temperature Range 0°C to 40°C
Storage Temperature -15°C to 60°C
Audible Noise 60dB MAX
Display LED+LCD
Standard Warranty 2 years
CERTIFICATION & STANDARDS
CE-EMC+LVD (EN6100-6-3:2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)
]]>
PV3900 TLV Series (AC:110/220V 8-12KW) https://www.mustpower.com/product/pv3900-tlv-series-ac110-220v-8-12kw/ Wed, 06 Mar 2024 11:29:57 +0000 https://www.mustpower.com/?post_type=product&p=23970 Low Frequency Solar Inverter PV 250V | MPPT 200A |DC 48V PV3900 TLV series is a multi-function inverter ,combining functions of inverter and MPPT solar charger controller, solar charger and battery charger to offer uninterruptible power support. The comprehensive LCD display offers userconfigurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and selectable input voltage based on different applications.]]> ■ Smart LCD setting(Working modes, Charge Current, Charge voltage, etc.)
■ Built-in MPPT solar charge controller 200A
■ MPPT efficiency max 98%
■ Powerful charge rate up to 200A
■ Inside BMS function
■ DC start &Automatic Self-Diagnostic Function
■ WIFI monitoring function (optional)
■ Compatible to generator
■ Parallel operation with up to 3 units

MODEL PV39-8048 TLV PV39-10048 TLV PV39-12048 TLV
Nominal Battery System Voltage 48VDC
Stand-alone mode Yes
Parallel operation 3 units
INVERTER OUTPUT
Rated power 8KW 10KW 12KW
Surge rating 24000VA 30000VA 36000VA
Capable of starting electric motor 4HP 5HP 6HP
Waveform Pure sine wave / same as input (bypass mode)
Nominal output voltage RMS 100V/110V/120V/200V/220V/240V
Inverter effciency(peak) >90%
Line mode efficiency >95%
Power factor 1.0
Typical transfer time 10ms(max)
AC INPUT
Voltage 220V/230V/240V
Selectable voltage range 90-280 VAC (APL)
Frequency range 50Hz / 60Hz
BATTERY
Low battery voltage cutoff 40-48VDC for 48VDC mode
Low battery voltage recover 42-50VDC for 48VDC mode
High battery voltage cutoff 60VDC for 48VDC mode
High battery voltage recover 57VDC for 48VDC mode
No-load loss <50W
AC CHARGER
Output voltage Depends on battery type (Supports lead-acid, gel, and lithium batteries)
Charger AC input breaker rating 100A
Overcharge protection S.D. 62.8VDC for 48VDC mode
Maximum charge current 10-140A (setting) battery terminal
BTS
Continuous output power Yes Variances in charging voltage & S.D. voltage base on the battery temperature
BYPASS & PROTECTION
Input voltage waveform Sine wave (grid or generator)
Nominal input frequency 50Hz or 60Hz
Overload protection (SMPS Load) Software + Circuit breaker
Output short circuit protection Software + Circuit breaker
Bypass breaker rating 63A
Max bypass current 80A
SOLAR CHARGER
Maximum PV charge current 200A
DC voltage 48V
Maximim PV array power 10000W 10000W 10000W
MPPT range @ operating voltage(VDC) 64~235VDC
Maximum PV array open circuit voltage 250VDC
Maximum effciency >98%
Standby power consumption <2W
MECHANICAL SPECIFICATIONS
Mounting Wall mount
Packing Wooden box
Machine Dimension (W*H*D)(mm) 439*660.5*233.2
Package Dimension (W*H*D)(mm) 782*314.5*520.5
N.W(kg) 55 62 69
G.W(kg) 73 80 87
OTHER
Operation temperature range 0°C to 50°C
Storage temperature 15°C to 60°C
Audible noise 60dB MAX
Communication WiFi
Display LED+LCD
Standard Warranty 2 year
CERTIFICATION & STANDARDS
CE-LVD (IEC62109-1:2010, EN IEC62109-2:2011); UL1741
]]>
PV1100 PLUS Series (1.2-2.4KVA) https://www.mustpower.com/product/pv1100-plus-series-1-2-2-4kva/ Wed, 06 Mar 2024 11:29:52 +0000 https://www.mustpower.com/?post_type=product&p=23957 Simulated Sine Wave Inverter 1.2~2.4KVA | PWM 50A | AC 10A/20A | PV 55V PV1100Plus is a cost effective , intelligent hybrid off grid solar inverter. The LCD display offers friendly user-configurable button adjustment such as battery charging current, AC/solar charger priority and DC priority. When battery voltage is low, it will automatically switch to AC grid to supply continuous power to the loads. It suitable for personal home use.]]> ■ Simulated sine wave inverter

■ Built-in 50A PWM Solar Charge Controller

■ MFD (multi-function display)

■ 10A or 20A standard charging current from utility

■ AC/solar priority for output via MFD

■ AC/solar priority for charging via MFD

■ 3 steps charging algorithm

■ Overload & short-circuit protection

■ Battery reverse polarity protection

■ Deep discharge protection

■ Auto restart while AC/solar is recovering

■ Adjustable solar and utility charging current

MODEL PV11-1200 Plus PV11-2400 Plus
Nominal Battery System Voltage 12VDC 24VDC
NVERTER OUTPUT
Rated Power 1200VA/720W 2400VA/1440W
Waveform Simulated Sine-wave
Nominal Output Voltage RMS 230V
Output Voltage Regulation +10/-18%
Output Frequency 50Hz/60Hz +/-1 Hz
Inverter Efficiency(Peak) >80%
Line Mode Efficiency >98%
Typical Transfer Time Typical 15~20ms 40ms max
AC INPUT
Voltage 230VAC
Selectable Voltage Range Narrow 170~280VAC
Wide 90~280VAC
Frequency Range 40Hz-70Hz (Auto sensing)
BATTERY
Nominal Input Voltage 12VDC 24VDC
Minimum Start Voltage 10.5VDC 21.0VDC
Low Battery Alarm 10.5VDC (min) 21VDC (min)
Low Battery Cutoff 10~12VDC (Can be set) 20~24VDC (Can be set)
High Voltage Cutoff 15.0VDC (max) 30.0VDC (max)
SOLAR CHARGER & AC CHARGER
Maximum PV Charge Current 50A (max)
Maximum PV Array Power 750W 1500W
PWM Range @ Operating Voltage 16~55VDC
Maximum PV Array Open Circuit Voltage 55VDC
Maximum Efficiency >95%
Standby Power Consumption <2W
AC Charger Voltage 14.4V(max) 28.8V(max)
AC Charging Current 10A / 20A (Can be set)
Maximum Charge Current 10-50A (Can be set)
BYPASS & PROTECTION
Nominal Input Frequency 40Hz – 70Hz
Overload Protection (SMPS Load) FUSE
Output Short Circuit Protection FUSE
Bypass Fuse Rating 10A
Max Bypass Current 10Amp
MECHANICAL SPECIFICATIONS
Machine Dimension (W*H*D)(mm) 295*230*85
Package Dimension (W*H*D)(mm) 365*295*140
N.W (kg) 2.7
G.W (kg) 13.5kg/4pcs
OTHER
Operation Temperature Range 0°C to 50°C
Audible Noise 50dB MAX
Warranty 2years
Display LED+LCD
]]>
PV1500 LV Series (AC:120V 1500VA) https://www.mustpower.com/product/pv1500-lv-series-ac120v-1500va/ Wed, 06 Mar 2024 11:29:52 +0000 https://www.mustpower.com/?post_type=product&p=23958 Off Grid Solar Inverter 1500VA | AC 120V | PV 100V It is a cost efective, inteligent solar inverter which accepts Solar & Utility input at the same fime. The comprehensive lCD display ofers user-conigurable and easy-accessible buton adjustment such as batery charging curent, AC/solar charger priority and DC priority,.When battery voltage islow,it will automatically switch to AC grid to supply continuous power to the loads.]]> ■ Built-in 30A MPPT Solar Charge Controller

■ 10A or 15A standard charging current from utility AC

■ 2 Output ports for DC load

■ AC/solar priority for charging via MFD

■ Different charging mode for different kinds of batteries

■ Overload & short-circuit protection, Battery reverse polarity protection, Deep discharge protection

■ Auto restart while AC/solar is recovering Adjustable solar and utilitycharging current

■ Support fast max charging current setting

■ Support two kinds of batteries: LiFePO4 Lithium Battery Packand Lead-acid Battery

■ Automatic activate lithium battery pack which is be over discharged no output when AC input is OK

MODEL PV15-0612 LV PV15-1012 LV PV15-1524 LV
Nominal Battery System Voltage 12VDC 12VDC 24VDC
NVERTER OUTPUT
Rated Power 600VA / 600W 1000VA / 1000W 1500VA / 1500W
Waveform Pure Sine Wave
Nominal Output Voltage RMS 120VAC
Output Voltage Regulation +10/-18%
Output Frequency 50Hz / 60Hz ± 1Hz
Inverter Efficiency (Peak) >90%
Line Mode Efficiency >95%
Typical Transfer Time Typical 10ms(UPS,UL) , Typical 20ms(APL,DEF)
AC INPUT
Voltage 120VAC
Voltage Range 74 ~ 145VAC ± 3%
Frequency Range 40 ~ 65Hz ± 2Hz
BATTERY
Note: Below Parameters (PB) Lead-acid Battery / (LI) LiFePO4 Lithium Battery Pack – 12V(4 Series) 24V(8 Series)
Nominal Input Voltage 12VDC 24VDC
Low Battery Cutoff 10.5VDC(PB) 11.5VDC(LI) 21.0VDC(PB) 23.0VDC(LI)
Low Battery Alarm 11.0VDC(PB) 12.0VDC(LI) 22.0VDC(PB) 24.0VDC(LI)
Low Battery Voltage Recover 12.5VDC(PB) 12.8VDC(LI) 25.0VDC(PB) 25.6VDC(LI)
High Battery Voltage Recover 14.5VDC(PB) 14.5VDC(LI) 29.0VDC(PB) 29.0VDC(LI)
High Battery Voltage Cutoff 15.0VDC(PB) 15.0VDC(LI) 30.0VDC(PB) 30.0VDC(LI)
Charger Voltage boost 14.4VDC(PB) 14.4VDC(LI) 28.8VDC(PB) 28.8VDC(LI)
Charger Voltage float 13.8VDC(PB) 14.4VDC(LI) 27.6VDC(PB) 28.8VDC(LI)
SOLAR CHARGER & AC CHARGER
Maximum PV Charge Current 40A (max)
Maximum PV Array Power 600W 1200W
MPPT Operating Voltage Range 15 ~ 75VDC 30 ~ 75VDC
Maximum PV Array Open Voltage 105VDC
Maximum Efficiency > 95%
AC Charging Current Max 40A (Can be set) 20A (Can be set)
Maximum Charge Current AC+PV 80A (Can be set) 60A (Can be set)
BYPASS & PROTECTION
Output Short Circuit Protection FUSE
Bypass breaker Rating 15A 20A 30A
Max Bypass Current 15A 20A 30A
Battery Fuse Current 50A * 2 50A * 3 40A * 3
DIMENSIONS
Machine Dimension (W*H*D)(mm) 320*264.5*95
Package Dimension (W*H*D)(mm) 390*335*167
N.W(kg) 4.5 4.7
G.W(kg) 5.4 5.6
OTHER
Operating Temperature Range 0°C to 45°C
Audible Noise 50dB MAX
Display LED+LCD
Standard Warranty 2 year
]]>